Tensix: MOP Expander
tenstorrent_tt_isa)Tenstorrent Wormhole B0 & Blackhole A0
main
Tensix, WormholeB0Summary
The Tensix frontend contains one so-called MOP Expander per Tensix thread. Once appropriately configured, a MOP expander allows a single incoming MOP (macro-op) instruction to be expanded out to a long sequence of instructions (up to 32639 on Wormhole, and more on Blackhole, which uses wider iteration counts), though typical configuration might result in something more like 10 to 100 instructions.
Reference Notes
# MOP Expander
The Tensix frontend contains one so-called MOP Expander per Tensix thread. Once appropriately configured, a MOP expander allows a single incoming `MOP` (macro-op) instruction to be expanded out to a long sequence of instructions (up to 32639 on Wormhole, and more on Blackhole, which uses wider iteration counts), though typical configuration might result in something more like 10 to 100 instructions.
The frontend _also_ contains a [Replay Expander](REPLAY.md) per Tensix thread, which serves a similar role to the MOP Expander, though the MOP Expander is typically used for repetitive looping instruction sequences, whereas the Replay Expander is typically used for linear non-looping sequences. The Replay Expander sits _after_ the MOP Expander in the frontend, so the MOP Expander can output [`REPLAY`](REPLAY.md) instructions as part of its looping sequence, and those `REPLAY` instructions will subsequently be expanded by the Replay Expander (the converse is not true; the expansion of a `REPLAY` instruction cannot contain `MOP` instructions). In either case, the expanders allow a RISCV core to push instructions at a rate of less than one instruction per cycle, but the Tensix backend to still receive one instruction per cycle per thread. This frees up the RISCV cores to perform other tasks, rather than having to spend every single cycle pushing a Tensix instruction.
## Instructions
The [`MOP`](MOP.md) and [`MOP_CFG`](MOP_CFG.md) instructions execute at the MOP Expander.
## Functional model
The MOP Expander sits at the start of the frontend of the Tensix coprocessor, before the Replay Expander. It is the sole place where `MOP` and `MOP_CFG` instructions are handled, and the only things it handles are `MOP` and `MOP_CFG` instructions. The behavior of the MOP Expander can be described as an asynchronous generator acting on the instruction stream:
```py
async def MOPExpander(MopCfg): # MopCfg is per-thread state
MaskHi = 0 # This is per-thread state, as there's an expander per thread
while True:
Instruction = await GetNextIncomingInstruction()
if Instruction.Opcode == MOP_CFG:
MaskHi = Instruction.MaskHi
elif Instruction.Opcode == MOP:
if Instruction.Template == 0:
async for x in ExpandTemplate0((MaskHi << 16) + Instruction.MaskLo, Instruction.Count1, MopCfg):
yield x
else:
async for x in ExpandTemplate1(Instruction, MopCfg):
yield x
else:
yield Instruction # Just pass through everything other than MOP and MOP_CFG
async def ExpandTemplate0(Mask, Count1, MopCfg):
Flags = MopCfg[1]
InsnB = MopCfg[2]
InsnA0 = MopCfg[3]
InsnA1 = MopCfg[4]
InsnA2 = MopCfg[5]
InsnA3 = MopCfg[6]
SkipA0 = MopCfg[7]
SkipB = MopCfg[8]
HasB = Flags & 1
HasA123 = Flags & 2
for i in range(Count1+1):
if (Mask & 1) == 0:
yield InsnA0
if HasA123:
yield InsnA1
yield InsnA2
yield InsnA3
if HasB:
yield InsnB
else:
yield SkipA0
if HasB:
yield SkipB
Mask >>= 1
async def ExpandTemplate1(Instruction, MopCfg):
if TTArchitecture == Blackhole:
OuterCount = MopCfg[0] & 1023
InnerCount = MopCfg[1] & 1023
if OuterOverride := (Instruction.Bits >> 10) & 1023: # instruction bits [19:10]
UnsupportedFunctionality() # No known usage, confidence in specification below is weak
OuterCount = OuterOverride
if InnerOverride := Instruction.Bits & 1023: # instruction bits [9:0]
UnsupportedFunctionality() # No known usage, confidence in specification below is weak
InnerCount = InnerOverride
else:
OuterCount = MopCfg[0] & 127
InnerCount = MopCfg[1] & 127
StartOp = MopCfg[2]
EndOp0 = MopCfg[3]
EndOp1 = MopCfg[4]
LoopOp = MopCfg[5]
LoopOp1 = MopCfg[6]
Loop0Last = MopCfg[7] # Overrides LoopOp or LoopOp1 on last iteration of inner loop, if also last iteration of outer loop
Loop1Last = MopCfg[8] # Overrides LoopOp or LoopOp1 on last iteration of inner loop, if not last iteration of outer loop
if IsNop(LoopOp1):
LoopOpFlip = 0
else:
LoopOpFlip = LoopOp ^ LoopOp1 # Inner loop will alternate between the two instructions and will
InnerCount *= 2 # execute for twice as many iterations. It is expressed like this
# because Loop0Last / Loop1Last override the last iteration.
if IsNop(StartOp) and InnerCount == 0 and not IsNop(EndOp0):
UnsupportedFunctionality() # No plausible utility, confidence in specification below is weak
if not IsNop(EndOp1):
if OuterCount == 1:
OuterCount += (1024 if TTArchitecture == Blackhole else 128) # Hardware bug
else:
OuterCount += 1 # Hardware bug
elif TTArchitecture == Blackhole and IsNop(StartOp) and InnerCount == 0 and not IsNop(EndOp1):
UnsupportedFunctionality() # Expands to nothing on its own, but straight after another MOP the inner loop runs anyway
for j in range(OuterCount):
if not IsNop(StartOp):
yield StartOp
for i in range(InnerCount):
if i != InnerCount-1:
yield LoopOp
elif j != OuterCount-1:
yield Loop1Last
else:
yield Loop0Last
LoopOp ^= LoopOpFlip
if not IsNop(EndOp0):
yield EndOp0
if not IsNop(EndOp1):
yield EndOp1
def IsNop(Instruction):
# This only recognizes plain NOP (opcode 0x02), not DMANOP nor SFPNOP.
return Instruction.Opcode == NOP
```
## Configuration
Each instance of `MopCfg` is mapped into the address space of one RISCV core as if it were `uint32_t[9]`, starting at address `TENSIX_MOP_CFG_BASE`, though the address range is **write-only**: attempting to read it from RISCV triggers `UndefinedBehavior`. RISCV T0 gets `MopCfg` for Tensix thread T0, RISCV T1 gets `MopCfg` for Tensix thread T1, and RISCV T2 gets `MopCfg` for Tensix thread T2. As per the above functional model, the meaning of each entry in `MopCfg` varies based on which template a `MOP` instruction requests:
||Template 0 usage|Template 1 usage|
|---|---|---|
|**`MopCfg[0]`**|Not used for anything|`OuterCount` (low seven bits on Wormhole; low ten bits on Blackhole)|
|**`MopCfg[1]`**|`Flags` (low two bits only; `HasB` and `HasA123`)|`InnerCount` (low seven bits on Wormhole; low ten bits on Blackhole)|
|**`MopCfg[2]`**|`InsnB` (only used if `HasB`)|`StartOp` (not used if it's a `NOP`)|
|**`MopCfg[3]`**|`InsnA0`|`EndOp0` (not used if it's a `NOP`)|
|**`MopCfg[4]`**|`InsnA1` (only used if `HasA123`)|`EndOp1` (not used if it's a `NOP` nor if `EndOp0` is a `NOP`)|
|**`MopCfg[5]`**|`InsnA2` (only used if `HasA123`)|`LoopOp`|
|**`MopCfg[6]`**|`InsnA3` (only used if `HasA123`)|`LoopOp1` (not used if it's a `NOP`)|
|**`MopCfg[7]`**|`SkipA0`|`Loop0Last`|
|**`MopCfg[8]`**|`SkipB` (only used if `HasB`)|`Loop1Last`|
On Blackhole, a template 1 `MOP` instruction can additionally override the `MopCfg`-sourced `OuterCount` and `InnerCount` using instruction bits [19:10] and [9:0] respectively (a non-zero field overrides the corresponding count); see the functional model. Use of these override fields has not been validated and is therefore `UnsupportedFunctionality`.
Though the functional model shows `MopCfg` being sampled at the start of `ExpandTemplate0` / `ExpandTemplate1`, actual hardware (mostly) samples the values as required during the expansion process. As such, software should not change `MopCfg` while an expansion is in progress. [RISCV TTSync](../BabyRISCV/TTSync.md) can be used to wait for expansions to finish, and software is strongly encouraged to use it prior to writing new MOP Expander configuration.
## Performance
While not processing `MOP` or `MOP_CFG` instructions, each MOP Expander can ingest one instruction per cycle and emit one instruction per cycle. When emitting instructions, the MOP Expander will resolve as much control flow as necessary to find the next `yield` statement, so the control flow is effectively free.
Upon receiving a `MOP` instruction, a MOP Expander will ingest the `MOP` instruction and then emit a different sequence of instructions, at a rate of one instruction per cycle, only slowing down if backpressured from downstream.
After expanding a `MOP` instruction, if the next instruction is _not_ a `MOP` instruction, there is a one cycle transition penalty during which the MOP Expander neither ingests nor emits anything. To ensure that the Tensix backend receives one instruction per cycle regardless of this penalty, at least one of the instructions emitted by the expander should be a `REPLAY` instruction which in turn needs to expand to at least two instructions.