cbo.inval
riscv_unified_db)RV32 / RV64 (Ratified & Standard Extensions)
main
userZicbomSummary
Either invalidates or flushes (clean + invalidate) a cache block, depending on the current mode and value of menvcfg.CBIE, senvcfg.CBIE, and/or henvcfg.CBIE.
Syntax / Encoding
cbo.inval (xs1) | 000000000000xxxxx010000000001111 (mask=0xfff07fff match=0x0000200f)
Binary Encodings (1)
| Width | Format | Bit Pattern | Mask / Match |
|---|---|---|---|
| 32 | RV | 000000000000xxxxx010000000001111 | 0xfff07fff / 0x0000200f |
Operands
| Name | Description |
|---|---|
xs1 | bits [19:15] |
Reference Notes
Either invalidates or flushes (clean + invalidate) a cache block, depending on the current mode and value of `menvcfg.CBIE`, `senvcfg.CBIE`, and/or `henvcfg.CBIE`. The instruction is an invalidate (without a clean) when: * In M-mode * In (H)S-mode and `menvcfg.CBIE` == 11 * In U-mode and `menvcfg.CBIE` == 11 and `senvcfg.CBIE` == 11 * In VS-mode and `menvcfg.CBIE` == 11 and `henvcfg.CBIE` == 11 * In VU-mode and `menvcfg.CBIE` == 11 and `henvcfg.CBIE` == 11 and `senvcfg.CBIE` == 11 Otherwise, if the instruction does not trap (see Access section), the operation is a flush. The table below summarizes the options. [%autowidth,cols="1,1,1,1,1,1,1,1",separator="!"] !=== .2+h![.rotate]#`menvcfg.CBIE`# .2+h! [.rotate]#`senvcfg.CBIE`# .2+h! [.rotate]#`henvcfg.CBIE`# 5+^.>h! `cbe.inval` Operation .^h! M-mode .^h! S-mode .^h! U-mode .^h! VS-mode .^h! VU-mode ! 00 ! - ! - ! Invalidate ! `Illegal Instruction` ! `Illegal Instruction` ! `Illegal Instruction` ! `Illegal Instruction` ! 01 ! 00 ! 00 ! Invalidate ! Flush ! `Illegal Instruction` ! `Virtual Instruction` ! `Virtual Instruction` ! 01 ! 00 ! 01 ! Invalidate ! Flush ! `Illegal Instruction` ! Flush ! `Virtual Instruction` ! 01 ! 00 ! 11 ! Invalidate ! Flush ! `Illegal Instruction` ! Flush ! `Virtual Instruction` ! 01 ! 01 ! 00 ! Invalidate ! Flush ! Flush ! `Virtual Instruction` ! `Virtual Instruction` ! 01 ! 01 ! 01 ! Invalidate ! Flush ! Flush ! Flush ! Flush ! 01 ! 01 ! 11 ! Invalidate ! Flush ! Flush ! Flush ! Flush ! 01 ! 11 ! 00 ! Invalidate ! Flush ! Flush ! `Virtual Instruction` ! `Virtual Instruction` ! 01 ! 11 ! 01 ! Invalidate ! Flush ! Flush ! Flush ! Flush ! 01 ! 11 ! 11 ! Invalidate ! Flush ! Flush ! Flush ! Flush ! 11 ! 00 ! 00 ! Invalidate ! Invalidate ! `Illegal Instruction` ! `Virtual Instruction` ! `Virtual Instruction` ! 11 ! 00 ! 01 ! Invalidate ! Invalidate ! `Illegal Instruction` ! Flush ! `Virtual Instruction` ! 11 ! 00 ! 11 ! Invalidate ! Invalidate ! `Illegal Instruction` ! Invalidate ! `Virtual Instruction` ! 11 ! 01 ! 00 ! Invalidate ! Invalidate ! Flush ! `Virtual Instruction` ! `Virtual Instruction` ! 11 ! 01 ! 01 ! Invalidate ! Invalidate ! Flush ! Flush ! Flush ! 11 ! 01 ! 11 ! Invalidate ! Invalidate ! Flush ! Invalidate ! Flush ! 11 ! 11 ! 00 ! Invalidate ! Invalidate ! Invalidate ! `Virtual Instruction` ! `Virtual Instruction` ! 11 ! 11 ! 01 ! Invalidate ! Invalidate ! Invalidate ! Flush ! Flush ! 11 ! 11 ! 11 ! Invalidate ! Invalidate ! Invalidate ! Invalidate ! Invalidate !=== `cbo.inval` is ordered by `FENCE` instructions but not `FENCE.I` or `SFENCE.VMA`. <%- if (CACHE_BLOCK_SIZE.bit_length - 1) > [PMP_GRANULARITY, PMA_GRANULARITY].min -%> Both PMP and PMA access control must be the same for all bytes in the block; otherwise, `cbo.inval` has UNSPECIFIED behavior. <%- end -%> Invalidate operations are treated as stores for page and access permissions. If permission checks fail, one of the following exceptions will occur: <%- if ext?(:H) -%> * `Store/AMO Guest-Page Fault` if virtual memory translation fails during G-stage translation. <%- end -%> * `Store/AMO Page Fault` if virtual memory translation fails <% if ext?(:H) %>when V=0 or during VS-stage translation<% end %> * `Store/AMO Access Fault` if a PMP or PMA access check fails. <%- if (CACHE_BLOCK_SIZE.bit_length - 1) <= [PMP_GRANULARITY, PMA_GRANULARITY].min -%> Because cache blocks are naturally aligned and always fit in a single PMP or PMA regions, the PMP and PMA access checks only need to check a single address in the line. <%- end -%> CBO operations never raise a misaligned address fault.