T1 riscv feature feature
Indexed Integer Load Instructions
SourceRISC-V Official Unified Database (riscv-unified-db) (riscv_unified_db)
Reliability TierT1 — Official Specification
ISA / Silicon Scopev0.1.0 (development)
RV32 / RV64 (Ratified & Standard Extensions)
License & VersionApache-2.0 / CC-BY-4.0
main
Upstreamhttps://github.com/riscv/riscv-unified-db
Note: Extension state: development

Summary

The Zilx extension provides integer load instructions that compute their effective address from a base register and an index register. The extension defines unscaled indexed loads and scaled indexed loads. On RV64, the extension also defines scaled loads that zero-extend the low 32 bits of the index register before scaling and forming the effective address.

Syntax / Encoding

Zilx v0.1.0 (development)

Reference Notes

The Zilx extension provides integer load instructions that compute their
effective address from a base register and an index register. The extension
defines unscaled indexed loads and scaled indexed loads. On RV64, the
extension also defines scaled loads that zero-extend the low 32 bits of the
index register before scaling and forming the effective address.

Each Zilx instruction uses `xs1` as the index operand and `xs2` as the base
operand, computes an effective address, loads a byte, halfword, word, or
doubleword from memory, and writes the extended load result to `xd`. The
operand roles match the shift-add instructions of the `Zba` extension, in
which the shifted operand is `xs1` and the added base is `xs2`.

Effective addresses are computed using XLEN-bit two's-complement address
arithmetic, and address arithmetic overflow is ignored:

* For an unscaled indexed load, the effective address is the low XLEN bits of
  `X[xs2] + X[xs1]`.
* For a scaled indexed load, the effective address is the low XLEN bits of
  `X[xs2] + (X[xs1] << log2(access-size))`, where _access-size_ is the number
  of bytes loaded by the instruction.
* For a scaled unsigned-word-index load (mnemonic prefix `lxsuw`), the index
  operand is zero-extended from `X[xs1][31:0]` to 64 bits before scaling.
  These instructions are defined only for RV64.

Byte loads are provided only as scaled forms (mnemonic prefixes `lxs` and
`lxsuw`). Because the scale factor for a byte access is 1, an unscaled byte
load would be identical to the scaled byte load, so no unscaled byte load is
defined. For convenience, `lxb` and `lxbu` are provided as assembler
pseudoinstructions for `lxsb` and `lxsbu`, respectively.

Zilx adds no architectural state, CSRs, or memory-ordering rules. Except for
the effective-address calculation, each Zilx instruction behaves as the
corresponding base integer load of the same access size and signedness, and
follows the same exception, address-alignment, access-fault, page-fault, PMP,
PMA, privilege, atomicity, and memory-ordering rules.

Zilx instructions reuse the `AMO` major opcode. The access width and
signedness are encoded in _funct3_ using the same encoding as base integer
loads, and the addressing mode is encoded in _funct5_. For all Zilx
instructions the _aq_ and _rl_ bits must be 0; encodings with _aq_ or _rl_
set are reserved.